POWER CONVERSION · OWN-FACTORY MANUFACTURING
Inverter & UPS
PCB Manufacturing
and Assembly
Power boards. Control electronics.
Complete power assemblies.
FLJ manufactures inverter and UPS PCBs and PCB assemblies, with power-component sourcing, mixed-technology assembly, module mounting and functional testing. From the populated board to the wired power unit, we build the hardware your product needs.

Inverter and UPS PCB Assemblies We Manufacture
FLJ supplies inverter power boards, gate-drive and control PCBAs, and UPS charging and backup-power assemblies. Our own-factory manufacturing combines fabricated PCBs, procured components and mixed-technology assembly, with power hardware and complete-unit integration available alongside board-level supply.

Solar and Energy-Storage Inverter Boards
Inverter power-stage boards carry switching devices and the power connections that convert energy between DC and AC. Related gate-drive and control boards provide switching commands, sensing and feedback; depending on the design, these functions may sit on separate boards or be combined. Energy-storage and bidirectional designs may also include a charging function, with operating requirements determined by the actual circuit and mode.
We manufacture boards for string and central solar inverters, compact microinverters and hybrid solar-storage equipment. Supply can include the main power stage, a separate control card, gate-driver boards and auxiliary power electronics. Bidirectional systems add charging operation to the same product’s manufacturing and verification requirements.

UPS Power, Charging and Control Boards
UPS assemblies can include an inverter board for battery-backed AC output, a charger board for restoring battery energy, and control or monitoring boards for sensing and coordinating operation. Some designs combine these roles. The required set depends on the UPS circuit and its operating modes.
For standby, line-interactive and double-conversion UPS products, we build the board set used by the selected power path. It may include relay or bypass control, battery connections, communications and monitoring alongside the power and charger circuits. We supply populated boards, connected subassemblies and complete power units to match the customer’s required delivery level.
Inverter and UPS PCB Manufacturing Capabilities
Power conversion boards combine high-current paths, heat-producing components and control circuits with different assembly needs. We manufacture bare boards and assemble inverter and UPS PCB assemblies, selecting the construction and connection route around the design, parts and operating demands.
PCB Materials, Copper and Interconnection Options
FR-4 and high-Tg multilayer constructions accommodate power and control circuits, while thicker copper serves the power paths that need it. Fabrication must preserve the specified insulation spacing, slots and plated connections as well as the circuit geometry.
Inverter and UPS PCB construction options
Scroll to view all columns.
| Construction item | Available options | Manufacturing detail |
|---|---|---|
| Base materials | FR-4, high-Tg FR-4; double-sided and multilayer boards | Stack-up, dielectric thickness and insulation geometry follow the power/control design. |
| Power-layer copper | 2–6 oz options; advanced finished outer layers up to 8 oz and inner layers up to 6 oz | Specify the finished copper on each layer. Starting foil and finished circuit copper are different quantities. |
| Copper and line/space | 3 oz: 7/7 mil · 4 oz: 12/12 mil 6 oz: 20/20 mil · 8 oz outer: 28/28 mil | These paired construction references show the geometry allowance for thicker copper; they are not interchangeable minimums. |
| Plated connections | Through-holes and specified module/connector interfaces | Hole-wall copper, finished hole and surface finish are specified separately from circuit-layer copper. |
One ounce of copper is nominally about 35 µm; 3 oz is about 105 µm and 6 oz about 210 µm. Current capacity also depends on path width, connections and temperature rise. Our heavy-copper PCB manufacturing service develops the thicker power layers within the required board construction.
SMT, Through-Hole and Press-Fit Assembly

SMT suits dense control, gate-drive and sensing packages. Power stages may combine surface-mount parts with through-hole (THT) terminals, large components and magnetics. Heavy copper and large leads draw heat from solder joints, so paste volume, stencil design, preheat and reflow profile must account for board and component thermal mass. Selective or wave soldering can serve suitable through-hole joints where multiple power planes or connector layouts affect heat flow. The route is chosen for the actual board and parts; see through-hole assembly.
Press-fit modules and connectors provide a solderless route. Their pins must match the PCB drill, finished hole, plated hole-wall copper and surface finish. Tool geometry, board support and alignment also matter; finished-hole diameter alone does not define a qualified fit. The assembly process needs component and board-specific qualification, with insertion monitored against the applicable specification. Some power modules instead use soldered connections, according to their package and mating PCB requirements.
Power Components, Custom Magnetics and Approved Alternatives
Inverter and UPS boards depend on parts that work together electrically and fit the assembled product. FLJ sources specified components and proposes alternative brands when availability, lead time or cost calls for another purchasing option. Our quotation identifies the proposed parts and commercial choices; a component change proceeds after customer approval.
Power Semiconductors and Drive Components
A MOSFET or IGBT cannot be selected by voltage and current labels alone. Its switching behavior, losses and package affect the gate-drive requirements, board connections and heat path. We compare the switch and its driver together: drive voltage and timing, pin arrangement, footprint, insulation where applicable, and the thermal path to the board or heatsink. Power-module package and pin style matter: soldered and press-fit connections require matching PCB designs; a similar family name does not establish interchangeability.
We compare the device and drive combination with design requirements and identify what needs sample-build confirmation. For capacitors and relays, the comparison includes operating ratings, terminals, footprint, spacing and mechanical fit. Availability and price are presented alongside the technical differences, so the customer can approve a purchasing option with its effect on the build understood.
Transformers, Inductors and Component Substitutions
For a custom transformer or inductor, procurement starts with the drawing and electrical requirements. Winding arrangement, core and winding dimensions, terminations, insulation needs, and board or enclosure clearance determine whether a part can be built and installed as intended. We can quote against those requirements and compare samples for fit and performance.
Where a magnetic part or other substitute affects circuit behavior, final acceptance requires evaluation in the actual circuit. A drawing match or supplier specification alone cannot confirm the result in an inverter or UPS. Our procurement support connects approved parts, sample findings and the manufacturing BOM. See our component sourcing service for related procurement support.
Power-Module Mounting and Complete Assembly
A power module’s thermal path and mechanical mounting affect the finished inverter or UPS together. FLJ can assemble the PCBA, mount specified power hardware, and integrate related wiring, cooling and enclosure parts to the delivery level defined for the project.

Thermal Interfaces, Contact Pressure and Mechanical Support
For a module construction that transfers heat through a mounting face to a heatsink, surface condition and contact pressure affect that path. The specified thermal interface fills surface irregularities, while controlled fastening maintains contact without distorting the module or board. Where the module arrives with factory-applied thermal interface material (TIM), handling and mounting preserve that interface as specified. Other constructions use a separately applied interface or a different cooling arrangement, including direct-liquid cooling. The module’s mounting instructions determine the applicable interface and fastening process.
Fasteners, washers and nearby hardware also occupy electrical clearance around power terminals. In a live power assembly, their position and insulation geometry must be considered in the installed condition, since screw heads or supports can change clearances from those of the bare module. A heatsink may also sit at an electrical potential determined by the device and insulation arrangement. Heavy heatsinks and modules need support that limits movement and avoids transferring load into PCB joints, terminals or nearby components. Support and fastening sequence follow the package and enclosure; torque is design-specific.
Power Wiring, Insulation and Enclosure Integration
Busbars and cables must fit the terminals and carry their mechanical loads without pulling on solder joints, press-fit contacts or module leads. Routing, bend space, insulation and strain relief are checked alongside terminal clearance and heatsink mounting. Fans need a clear airflow path and secure connections, while the enclosure must provide the intended hardware fit, access and cooling path.
Delivery can stop at an assembled PCBA, include a mounted power-stage subassembly, or extend to a complete inverter or UPS unit with its heatsink, wiring, fans and housing as specified. This lets customers match the build scope to their own downstream work. Related box-build assembly and cable assembly services cover enclosure integration and connected wiring where those items are included in the agreed build.
Inspection, Functional Testing and Load Verification
FLJ inspects the assembled board, loads the released firmware and carries out the functional checks required for the supplied board or power unit. Workmanship and net checks, controller operation and energized conversion are separate verification tasks.
Board Inspection, Programming and Control Checks
Assembly checks include visual inspection of solder joints, polarity, component placement and power connections, then continuity or fixture checks for specified nets and isolation where required. They do not demonstrate conversion under load.
For boards requiring firmware, programming loads the specified controller image and confirms access and configuration. With the controller powered and the main power stage isolated where appropriate, checks can exercise sensing channels, status signals, fault inputs, interlocks and commanded switching logic against expected behavior. These checks verify control paths, not conversion. See IC programming and functional testing.

Inverter Load Tests and UPS Operating Modes
Powered verification matches the conversion path. Stand-alone AC output uses a suitable AC load; grid-connected verification establishes the specified grid conditions with a suitable grid simulator. PV or storage operation may require a corresponding source or battery simulator. Bidirectional equipment is checked in each applicable direction because charging and inversion have different power-flow criteria.
Inverter and UPS functional test conditions
Scroll to view all columns.
| Object | Source, input, mode and load | Observed outcome |
|---|---|---|
| Stand-alone AC output | Specified DC source; inverter mode; suitable AC load | Output voltage and frequency behavior, waveform shape, regulation under the tested load, and applicable fault response |
| Grid-connected conversion | Suitable grid simulator; configured DC or PV input; grid mode | Synchronization and measured AC output behavior under the defined conditions, including configured protection response |
| Bidirectional storage conversion | Battery simulator or suitable DC source/sink; charge and discharge modes | Power-flow direction, control response, measured DC/AC behavior and applicable limits or shutdown response |
| UPS charging | Specified AC input; battery or suitable battery simulator at the required condition | Charge voltage/current response, state control and applicable charging protections |
| UPS backup and restoration | Defined battery condition and AC load; input loss and return | Backup output, mode-change waveform and restoration behavior for the actual topology |
| UPS transfer or bypass, where fitted | Input change or commanded bypass; representative load | Transfer sequence, output behavior and return from bypass against the design’s expected operation |
Test records relate the assembly revision and firmware to the source, load, operating mode and measured result. UPS transfer and bypass checks use the expected behavior of the actual topology. Specified burn-in or environmental stress screening can extend the verification plan to duration, temperature or vibration conditions; these checks remain separate from complete-product certification.
Inverter and UPS PCB Assembly FAQs
Can FLJ supply power boards, control PCBAs and complete inverter assemblies?
Yes. We manufacture inverter power-stage and gate-drive or control boards, plus UPS charging and transfer assemblies. Supply can be a populated PCBA, tested power subassembly or complete inverter unit.
What copper weights and PCB constructions are available?
We offer FR-4 and high-Tg double-sided or multilayer boards, with 2–6 oz power-layer options. Advanced finished copper extends to 8 oz outer layers and 6 oz inner layers, with geometry matched to copper thickness.
Can you assemble both soldered and press-fit power modules?
Yes. We assemble the connection type specified for the module and mating PCB. Soldering must suit the part’s thermal mass. Press-fit requires matched pins, matched holes, plating, tooling and support; hole diameter alone is insufficient.
Can you source custom magnetics and quote alternative component brands?
Yes. We can procure custom transformers or inductors to a drawing and winding specification, then review fit and circuit behavior. We can quote available approved brand alternatives after checking package and thermal needs.
Can heatsinks, power connections and enclosures be included?
Yes. Integration can include module-to-heatsink contact, thermal interface material where used, fastening, power wiring or busbars with strain relief, fans and enclosure fit. Insulation follows design requirements.
How are control boards and power stages tested?
Control checks can cover connection inspection, programming and control functions. Power-stage tests energize the converter in the agreed mode and observe output with a suitable load or simulated input.
Do all UPS assemblies transfer to battery power without interruption?
UPS transfer behavior depends on topology and operating mode. Standby and line-interactive designs typically switch to battery when input fails; double-conversion normally powers the load through conversion. Zero transfer is not universal; check bypass or ECO modes.
What information is needed for a manufacturing quotation?
Provide PCB fabrication files, a BOM and placement data, quantity, delivery level and test requirements. Include drawings for custom magnetics, heatsinks and enclosures, plus any approved-alternative constraints. Prepare a manufacturing inquiry to discuss the build.
Discuss your PCB, component requirements, mechanical assembly and test scope.
Related power-control examples
Explore the board images, product information and design details for related projects.
Solar Power System Control Board
Solar power control electronics for battery charging, discharging and load supply, with PWM charging regulation described for the design.
Power Control System PCB Assembly
Relay-equipped PCB assembly for a power-control system, with surface-mounted components, pin headers and a multi-pin connector.