A six-layer stackup contains six copper layers separated by five dielectric regions. In one conventional foil build, two double-sided cores form the four inner copper layers. Prepreg bonds the cores to each other and to the outer copper foils. The outer circuits are then processed as part of the plated board.
Core and prepreg describe materials; signal, ground and power describe electrical functions. Assigning a ground layer does not determine its core thickness, and choosing a prepreg cloth does not by itself define the final pressed dielectric gap.
From a layer sequence to a physical construction
For the three-signal-layer example, the top signal is next to L2 ground, the internal signal on L3 is next to that same ground layer, and the bottom signal is next to L5 ground. L4 power and L5 ground form an adjacent plane pair. Changing the dielectric gaps changes how strongly those neighboring conductors couple.
The illustration separates those electrical roles from the core and bonding regions. It represents one construction, rather than a standard thickness recipe. Other core and foil arrangements can produce six copper layers with different local geometry.
Five dielectric regions do not mean five sheets of prepreg. A bonding region may contain more than one ply, while a cured core already separates two copper layers. Resin content, adjacent copper pattern and pressing conditions affect the resulting bonding thickness. The finished construction brings those material choices together with the required electrical spacing.
Use the thickness that belongs to the question
Finished board thickness sets the mechanical envelope for the enclosure, mounting hardware and connector engagement. Signal-to-reference spacing is a local dimension inside that envelope. Two boards with the same finished thickness can place a signal very differently relative to its reference plane.
Impedance routing depends on that local spacing together with material properties, finished conductor width and thickness, and differential-pair spacing where relevant. Etching and plating affect the conductor geometry; resin flow and curing affect the bonding dielectric. Calculations should therefore describe the fabricated construction rather than substitute the initial material thicknesses.
The stackup specification connects these requirements: layer sequence, laminate and prepreg construction, pressed dielectric values and finished copper. It provides the common geometry for layout and fabrication.